Skip to content
InvardiaInvardia
Why InvardiaProductsFeaturesPricingCommunity
Docs
All documentation
Product documentationPIM ManagerSecurityInsight
SettingsPIM Manager settingsSecurityInsight settingsEntra Policy Suite settings
ScriptsPIM Manager scriptsSecurityInsight scriptsEntra Policy Suite scriptsInvardia scripts
Error codesPIM Manager error codesSecurityInsight error codes
API and MCPPIM Manager APIPIM Manager MCP toolsSecurityInsight APISecurityInsight MCP tools
SecurityPIM Manager security packSecurityInsight security packEntra Policy Suite security pack
Network and designPIM Manager network guidesPIM Manager command wizardNetwork egressDesign your installationCalculate your cost
SupportSetup scriptsRemote support access
Search the docs
SupportAboutContactBook a demoCustomer portalDesign your installationFree Pro trial

SecurityInsight settings · Settings > Data & retention

Copy findings per CI to Log Analytics (SI_Finding_CL)

KeySI_RA_Findings
WhereSettings > Data & retention > Where collected data goes
TypeOn / off
DefaultOff: the findings per CI are kept in the database only
EditionCommunity
ConfirmationSecurityInsight asks you to confirm before it is switched on.

What it does

Optional. After each Risk Analysis Detailed run, copies the de-duplicated findings (one row per CI and finding) into your Log Analytics workspace, for your own workbooks, Sentinel or KQL. SecurityInsight itself does not need it: its pages read the findings from its database. On a large estate the copy can take hours and adds Log Analytics ingestion cost. Off by default.

When enabled

at the end of every Risk Analysis Detailed run its findings per CI are also posted to SI_Finding_CL, and the run ends when the copy has ended. On a large estate that is hours, and it costs ingestion for every finding, every run. The data sync reads that copy back only when it is the newest and whole; otherwise it makes the findings per CI from the database, as it does with the copy off.

When disabled

nothing is copied. This is not the Risk Analysis report rows (SI_RiskAnalysis_Detailed_CL): they are their own optional output, Copy Risk Analysis report rows to Log Analytics, off by default.

Risk and how to reverse it

Longer Risk Analysis Detailed runs and Log Analytics ingestion cost for every finding, every run. SecurityInsight itself does not need the copy. Reversible: turn it off and the next run copies nothing.

Requires

Nothing else.

Recommended

Off, unless your own workbooks, Sentinel rules or KQL read SI_Finding_CL.

Documented for SecurityInsight 3.0.79. Written by the SecurityInsight team; Invardia publishes it. · All settings · Security review pack

InvardiaInvardia

See the risk. Control the access.

Products

PIM ManagerSecurityInsightEntra Policy SuiteAll featuresPricingFree 60-day Pro trialBook a demoWhy Invardia

Docs

DocumentationSearch the docsPIM Manager settingsSecurityInsight settingsPIM network guidesCommand wizardNetwork egressPIM Manager design configuratorSecurityInsight design configuratorDesign your installationCalculate your cost

Company

AboutContactCustomer portalSupportHow support worksHow updates reach youSupport in numbersSetup scriptsRemote support accessContact: info@invardia.com

Legal

Terms of saleLicence termsData processingPrivacyCookiesCompany information
© 2026 Invardia – a brand of 2LINKIT, founded and owned by Morten Knudsen · Strandvejen 21A, 6000 Kolding, Denmark · VAT DK39208032 · Contact: info@invardia.com