SecurityInsight settings · Settings > Data & retention
Closed finding history kept
| Key | SI_Pro_FindingStateRetentionDays |
|---|---|
| Where | Settings > Data & retention |
| Type | int |
| Default | 365 days |
| Edition | pro |
What it does
How many days a closed finding's lifecycle row (first detected, closed, close reason) is kept in the Pro database.
When set
Closed lifecycle rows older than this are removed after each data sync; open findings are never removed.
When blank or default
Left blank, the default applies: 365 days
Risk and how to reverse it
Changes how long data is kept or how quickly assets are treated as gone. Shortening a retention DELETES older data at the next clean-up and that cannot be undone; shortening a grace period retires assets (and closes their findings) sooner. Lengthening is safe but uses more storage.
Requires
A SecurityInsight Pro licence.
Recommended
Keep the default. Change it when: Lengthen it when you report on fixes over a longer period.
Documented for SecurityInsight 3.0.79. Written by the SecurityInsight team; Invardia publishes it. · All settings · Security review pack