Skip to content
InvardiaInvardia
Why InvardiaProductsFeaturesPricingCommunity
Docs
All documentation
Product documentationPIM ManagerSecurityInsight
SettingsPIM Manager settingsSecurityInsight settingsEntra Policy Suite settings
ScriptsPIM Manager scriptsSecurityInsight scriptsEntra Policy Suite scriptsInvardia scripts
Error codesPIM Manager error codesSecurityInsight error codes
API and MCPPIM Manager APIPIM Manager MCP toolsSecurityInsight APISecurityInsight MCP tools
SecurityPIM Manager security packSecurityInsight security packEntra Policy Suite security pack
Network and designPIM Manager network guidesPIM Manager command wizardNetwork egressDesign your installationCalculate your cost
SupportSetup scriptsRemote support access
Search the docs
SupportAboutContactBook a demoCustomer portalDesign your installationFree Pro trial

SecurityInsight settings · Settings > Data & retention

Retire at once: objects deleted in Entra ID

KeySI_DeletionProof_Entra
WhereSettings > Data & retention > Assets no longer seen
TypeOn / off
DefaultOff: a user, device or group Entra ID no longer lists waits the not-seen grace period, as before
EditionCommunity
ConfirmationSecurityInsight asks you to confirm before it is switched on.

What it does

Retires an asset at once when Entra ID PROVES its object was deleted: the user, device or group is in Entra ID's deleted items. Merely missing from a list is never proof -- it keeps the not-seen grace period.

When enabled

Stages: the CI build checks the Entra ID records (and the Exposure Graph users and groups) missing from a complete collection against Entra ID's deleted items; a proven one is recorded, its CI retires at once ('retired at once: deleted in Entra ID') -- the proof wins over the grace period -- and its open vulnerabilities close as 'asset deleted in Entra ID', never as fixed. A CI another source still sees stays active. An object restored in Entra ID is listed again: its CI is active again and its findings reopen. A read that is not complete decides nothing for what it did not return.

When disabled

a user, device or group Entra ID no longer lists waits the not-seen grace period, as before

Risk and how to reverse it

Assets of objects deleted in Entra ID retire from the next CI build and their vulnerabilities close as deleted (ServiceNow closures follow). Reversible: turn it off and the next build decides them by the grace period again.

Requires

Read access to Entra ID's deleted items (Directory.Read.All, which the engine identity already has).

Recommended

Off, unless your organisation chose it.

Documented for SecurityInsight 3.0.79. Written by the SecurityInsight team; Invardia publishes it. · All settings · Security review pack

InvardiaInvardia

See the risk. Control the access.

Products

PIM ManagerSecurityInsightEntra Policy SuiteAll featuresPricingFree 60-day Pro trialBook a demoWhy Invardia

Docs

DocumentationSearch the docsPIM Manager settingsSecurityInsight settingsPIM network guidesCommand wizardNetwork egressPIM Manager design configuratorSecurityInsight design configuratorDesign your installationCalculate your cost

Company

AboutContactCustomer portalSupportHow support worksHow updates reach youSupport in numbersSetup scriptsRemote support accessContact: info@invardia.com

Legal

Terms of saleLicence termsData processingPrivacyCookiesCompany information
© 2026 Invardia – a brand of 2LINKIT, founded and owned by Morten Knudsen · Strandvejen 21A, 6000 Kolding, Denmark · VAT DK39208032 · Contact: info@invardia.com