Skip to content
InvardiaInvardia
Why InvardiaProductsFeaturesPricingCommunity
Docs
All documentation
Product documentationPIM ManagerSecurityInsight
SettingsPIM Manager settingsSecurityInsight settingsEntra Policy Suite settings
ScriptsPIM Manager scriptsSecurityInsight scriptsEntra Policy Suite scriptsInvardia scripts
Error codesPIM Manager error codesSecurityInsight error codes
API and MCPPIM Manager APIPIM Manager MCP toolsSecurityInsight APISecurityInsight MCP tools
SecurityPIM Manager security packSecurityInsight security packEntra Policy Suite security pack
Network and designPIM Manager network guidesPIM Manager command wizardNetwork egressDesign your installationCalculate your cost
SupportSetup scriptsRemote support access
Search the docs
SupportAboutContactBook a demoCustomer portalDesign your installationFree Pro trial

SecurityInsight settings · Settings > Connectors & CMDB

Data out: ServiceNow staging status table

KeySI_DataOut_ServiceNowStagingStatusTable
WhereSettings > Connectors & CMDB
TypeText
Defaultu_si_staging_status. An install that sent to ServiceNow before the staging status table existed has it empty: the rows are sent without it, with a warning, until your ServiceNow team creates the table and you set its name here.
EditionCommunity

What it does

The ServiceNow import set table where SecurityInsight says when each push of a ServiceNow output starts (writing) and ends (complete, failed or held). Every data row carries the same batch id, so your importer imports a batch only once it is complete.

When set

Set: each push is one batch -- a writing row first, the batch id on every data row, then a complete, failed or held row. If the table is missing or lacks a column, nothing is sent. Empty: the rows are sent without a batch, and the ServiceNow check warns.

When blank or default

Left blank, the default applies: u_si_staging_status. An install that sent to ServiceNow before the staging status table existed has it empty: the rows are sent without it, with a warning, until your ServiceNow team creates the table and you set its name here.

Risk and how to reverse it

Set to a table that does not exist on the instance, nothing is sent to ServiceNow until it is there (the ServiceNow check says why). Empty, your importer cannot tell a finished push from one that stopped halfway. Reversible at once.

Requires

A ServiceNow output switched on (SI_DataOut_Outputs), the ServiceNow data-out connector and the table created in ServiceNow.

Recommended

Keep the default. Change it when: After your ServiceNow team has created the staging status table (Connectors > the ServiceNow data-out connector > For your ServiceNow team), if it has another name than the default -- or, on an install that has it empty, to switch it on.

Documented for SecurityInsight 3.0.79. Written by the SecurityInsight team; Invardia publishes it. · All settings · Security review pack

InvardiaInvardia

See the risk. Control the access.

Products

PIM ManagerSecurityInsightEntra Policy SuiteAll featuresPricingFree 60-day Pro trialBook a demoWhy Invardia

Docs

DocumentationSearch the docsPIM Manager settingsSecurityInsight settingsPIM network guidesCommand wizardNetwork egressPIM Manager design configuratorSecurityInsight design configuratorDesign your installationCalculate your cost

Company

AboutContactCustomer portalSupportHow support worksHow updates reach youSupport in numbersSetup scriptsRemote support accessContact: info@invardia.com

Legal

Terms of saleLicence termsData processingPrivacyCookiesCompany information